| Basic unit with 8 probes (4 top, 4 bottom) Universal shuttle system with clamp and stretch mode for testing HDI and substrate boards. Pneumatic clamping function controlled by foot switch. |

| Max. board size (X x Y) | 640 mm x 610 mm / 25.2” x 24.0” |
|---|---|
| Min. board size (X x Y) | 10 mm x 10 mm / 0.4” x 0.4” |
| Test area (X x Y) | 610 mm x 510 mm / 24.0” x 20.0” |
| high resolution | mixed cameras | |
| Smallest pad | 25 ?m / 1.0 mil* | 35 ?m / 1.4 mil (top) 25 ?m / 1.0 mil* (bottom |
| Smallest pitch | 50 ?m / 2.0 mil | 75 ?m / 3.0 mil (top) 50 ?m / 2.0 mil* (bottom) |
| Board thickness | up to 2 mm / 0.08” | up to 4 mm / 0.16” |
| Resolution measurement system | ± 0.1 ?m / ± 0.004 mil | |
| Repeatable accuracy | ± 3 ?m / ± 0.12 mil | |
| Soft touch probes | 5 g to 10 g | |
| *Micro needle probes | 0.3 g to 2.5 g | |

| Continuity test | 1 Ω to 10 kΩ |
|---|---|
| Isolation test | up to 25 MΩ (FM) up to 100 GΩ (ohmic) MicroShort Detection® |
| Test voltage | 100 mV to 1000 V |
| 4 high resolution color cameras for fast optical scanning of top and bottom side.Resolution 3 ?m/ pixel or 2 high resolution color cameras of bottom side, Resolution 3 ?m/ pixel and 2 standard color cameras for top side, Resolution 6 ?m/ pixel for fast optical scanning |
| 4-wire measurement with max. 300 mA test current | ||
| 0 Ω to 1 kΩ | ±2 %, min ±25 ?Ω | |
|---|---|---|
| with Kelvin probes | 0.3 g to 2.5 g | |
| high resolution | mixed cameras | |
| Smallest pad | 60 ?m / 2.4 mil* | 80 ?m / 3.2 mil (top) 60 ?m / 2.4 mil* (bottom) |
| Smallest pitch | 100 ?m / 4.0 mil* | 120 ?m / 4.8 mil (top) 100 ?m / 4.0 mil* (bottom) |
| * special setup | ||
| Embedded components test | |
| R | 0 Ω to 1 MΩ ± 1 %, min. ± 0.5 Ω 1 MΩ to 200 MΩ ± 3 % |
|---|---|
| C | 0 F to 100 ?F ± 2 %, min. ± 30 fF |
| L | 0 H to 10 mH ± 5 %, min. ± 0.25 ?H |
| Diode / Varistor | UF,UR, UBR 0 V to 12.5 V |
| Retest of fault files from external grid test systems on inquiry | |
| Repair software with barcode support | |
| Required Utility | |
| Data Input Format | IPC-D-356A |
|---|---|
| Network Connection | Ethernet, TCP / IP |
| Power Supply | 3 x 400 V, 50 Hz (3 x 208 V, 60 Hz), 1500 VA |
| Compressed Air | 8 bar / 115 psi, filtered |
| Temperature | 19 °C to 23 °C |
| Relative Humidity | 40% to 60% |
| Machine Weight | 1450 kg |